Digital Incubator
www.R-com.co.kr
󰚟PX-20D, PX-20DUSB(Professional)
Ver E 3.1
New Rcom Pro 20 USER'S MANUALNew Rcom Pro 20 USER'S MANUAL
Species of Birds
1
2
4
3
5
6
Chicken
< USB MODEL >
Bird Icon Display
7
8
9
10
11
37.5
40
OFF
"All Reset"
℃↔℉
"OFF"
4 times
MENU
MENU
MANUAL
MANUAL
MANUAL
ENTER
ENTER
ENTER
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
SET󰚟UP
BACK
DOWN
SET󰚟UP
BACK
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
System finish
Are you sure?
R
E
A
R
R
E
A
R
FR
ON
T
PC󰚟SOFTWARE
<󰚟USB󰚟MODEL󰚟>
<󰚟USB󰚟MODEL󰚟>
Insert the electric cord in the connecting socket at the back of the Main body and
put the power cord into the outlet. The display will come on.
Place your eggs and cover the view window.
There can be some odor the first time you use the incubator, that is normal.There can be some odor the first time you use the incubator, that is normal.
Check the water level every three days and refill fully on incubation period.
The light for water top-up can remain for a while after you filled up.
Check the water level every three days and refill fully on incubation period.
The light for water top-up can remain for a while after you filled up.
The egg to incubate must be a fertilized egg. The egg to incubate must be a fertilized egg.
You should stop to fill in the water as soon as the Styrofoam ball floats on.
The ball will block the hole when full.
After filling up with water, never shake or turn over the main body of the incubator.
Be careful to close the view window completely; if not, the temperature will fail
to go up.
W
A
T
E
R
W
A
T
E
R
RE
A
R
R
EA
R
F
R
O
NT
standard egg tray
Egg turning Plate
Egg turning Plate
MENU
MANUAL
SHIFT
SET󰚟UP
BACK
ENTER
UP
DOWN
DIGITAL INCUBATOR
New
Dig i t al In c ub a t or
Chicken
37.5
55
W
A
TER
Egg Tray
Small, Standard,
or Large egg tray
according to egg size.
Universal Tray
(Sold Seperately)
1. Safety Cautions
Electrical hazards
Be careful the details below when you use.
Setting Cautions
Be careful the details below when you use.
Do not pull the cord when
taking out the power cord,
and keep wet hands away
from connecting plug.
Do not use a damaged
power cord or loose
outlet.
Risk of electric shock or fire.Risk of electric shock or fire.
Do not insert multiple
connecting plugs in an
outlet.
Risk of fire or electrical overload.
Never pull the plug out of
the outlet during the
incubation period.
Incubation will be interrupted.
Do not twist or crush
electric cord.
Risk of electric shock or fire.
Cleaning Cautions
Be sure to disconnect the electric cord
from the outlet before cleaning.
Clean the incubator by a
soft cloth with a neutral
detergent.
Do not spray cleanser
directly on the incubator
surface.
Do not use chemicals like wax,
benzene, alcohol, thinner,
aromatic, or lubricant, etc.
Brush away dust on the
plug with a dry cloth.
For special cleaning of
inner part per year, contact
to the service center.
Do not install under the
direct sunlight.
Do not install in dusty or
dirty environment.
Risk of fire or interference with
the incubation process.
Risk of damage or fire within
the incubator.
Do not install in excessively
cold or hot conditions,
cigarette smoke, etc.
Do not install in moist or
humid environment.
Risk of interference with
the incubation process.
Risk of fire or electric shock.
Do not use any other
non-standard parts
except those provided.
Risk of damage or hatching
failure.
Please ensure that no
small objects get into
the holes on the incubator.
Risk of electric shock or fire.
Do not disassemble or
modify the incubator in
any way.
Risk if electric shock or fire.
If the incubator sounds
strange or emits smoke
contact your service
center.
Risk of electric shock or fire.
If the incubator requires
repair disconnect from the
power supply and please
contact to your service center.
Clean the incubator
thoroughly before storing.
Install away from heat
sources.
Risk of damage to the incubator
case and interference with
the incubation process.
Do not turn the incubator
upside down.
Water will pour out of the incubator,
and view window can be dropped
or damaged.
Ensure that the incubator is
installed on a stable surface
away from edges.
Risk of damage to incubator
and eggs and user from
accidental knocks or drops.
Do not cover the
ventilating opening.
Inner temperature can rise,
interrupting incubation.
Do not install where
children or other people
can touch with easy.
Risk of knocking the incubator
or accidental interference with
the controls.
Main Body-1
Main Body-2
Locking Button
See description of
the function and operation.
Digital Control Center
View Window
For a clear view of
the incubation process.
( duplicated View Window )
Vents for air circulation
For circulating warm air
4. How to Assemble
5. How to Replace Fuse
Lock the three locking
buttons at the front and rear
of the incubator.
Insert the power cord
in the socket at the back
of the main body.
3. Basic Components
Power Cord
User's Manual
View Window
Main Body-2
Main Body-1
Water Cap
View Window
Main Body-1
Main Body-2
For inlet of air
from outside
Air inlet vent
Power Connecting
For connecting
power cord.
To facilitate water top-up
for the humidity control.
Water Cap
- Select Auto/Manual,
- Pass to next stage
- Temp. & Humidity UP
- Setting Value Change
- Select Reptiles
- Incubation Termination
Menu Button
Select Button
Function
Button
- Other function display
- Return to previous stage
- Enter input value,
Pass to next stage
- Setting Value Check
Up Button
Input Button
Down Button
8. Display Part Explanation
ICON NAME AND FUNCTION
FAN Operation Display
ICON NAME AND FUNCTION
Current Humidity Display
Humidification function OFF
Current Temperature Display
Temperature Abnormal Display
9. SET UP(Other Functions)
Heater Stop Display
Heater Operation Display
Humidification Stop Display
Humidification Operation Display
2 Sec.
Screen
on Incubation
Screen
on Incubation
Select
the Species of Bird
Select
the Species of Bird
UNDER 30%
REFER TO "HOW TO START INCUBATION" FOR MORE INFORMATION.
Automatic Mode
Incubation
Other(Manual) Mode
Incubation
How to change Setting under Incubation
(MANUAL)
Incubation
Termination
Incubator Initialization
(Factory Setting)
How to change
How to turn off
Humidification Function
(In󰚟case󰚟of󰚟low󰚟humidity󰚟incubation)
Select YES
10. Easy Function Operation
Temp. Setting
Humid. Setting
Egg Turning Angle Setting
Egg Turning Interval Setting(Incubation day)
Once: Temp. Setting
Four times: Humidity Setting
Seven times:
Egg Turning Angle Setting
Nine times: Egg Turning Interval Setting
Small Egg Tray
Standard Egg Tray
Large Egg Tray
Universal Tray
(Option)
USB Cable
Program CD Included
2. Identification of Parts
6. Before use
7. Operation Part
Egg Turning Indication
Manual Egg Turning Stop Indication
Automatic Egg Turning Stop Indication
Incubation Termination
PC Connecting
Alarm
You can turn off humidification function when you don't fill water with your incubation
or when you need low humidity incubation under 30%.
(Water supplement alarm will turn off with this function.
Refer to "How to turn OFF humidification function.")
Open the watercap and fill the hole with clean water. And, refill water after 5 min.
The styrofoam ball floats on and blocks the hole when full.
(Humidity goes down temporarily, in case you refill water under incubation period.)
Replace with new fuse.
( 250V 2.0A Ø5*20mm )
When the machine failed to
power on even if you plugged in,
remove the fixing piece like
the picture by screwdriver.
You can find assembled PCB
when open the cover.
Remove faulty fuse with screwdriver.
- Temp. & Humidity DOWN
- Setting Value Change
**Ch oose󰚟a󰚟k i nd**
*󰚟Chicken󰚟①
*󰚟Duck󰚟②󰚟
*󰚟Quail󰚟③󰚟
*󰚟Pheasant󰚟④󰚟
*󰚟Peafowl󰚟⑤󰚟
*󰚟Goose󰚟⑥󰚟
*󰚟wildgoose󰚟⑦󰚟
*󰚟G-Pheasant󰚟⑧󰚟
*󰚟Turkey󰚟⑨󰚟
*󰚟Others󰚟Birds󰚟⑩󰚟
Water Supplement
Humidity Abnormal
Power Failure Notification
1h
90˚
Egg Turning Interval Indication (per hour)
Egg Turning Angle Indication
WARNING
Fatal Damage
with Incorrect Calibration
WARNING
Fatal Damage
with Incorrect Calibration
Info
ALL󰚟RESET
󰚟󰚟ALL󰚟RESET
Factory setting
Alarm sounds when incubator temp. is higher than setting value
because of room temp. change or heating system disorder
*󰚟Setting Range : 0.0~5.0 (Default Setting : 2.0)
Alarm sounds when incubator temp. is lower than setting value
because of room temp. change or heating system disorder
* Setting Range : 0.0~5.0 (Default Setting : -3.0)
Uni t
A LA RM
󰚟Abnomal
High Alarm
A LA RM
Abnomal
low Alarm
Hi gh
T emp
Hi Er r
Low
T emp
LoEr r
Sound
Li ght󰚟
*󰚟Always On : Always BackLight On
*󰚟Event On : 20 Sec. ON with Key input
*󰚟Always Off : Always BackLight Off
* Default Value : Always On
LCD Backlight management setting
It returns to factory setting when you change the initial setting at discretion.
ON/OFF Setting for Melody, other alarms
* Default Value : ON
Basic information of Incubator (versoin Indication)
T.CAL
Temperature
Calibration
Selecting Centigrade (
o
C) and Fahrenheit (
o
F)
*󰚟Default Value : Centigrade (
o
C)
H.CAL
󰚟 Humidity
Calibration
Temp. calibration limits : -9.9 ~ +9.9
Be sure to read CAUTIONS. ( Calibration available after 5 Sec. )
H
u
m
i
d
i
t
y
c
a
l
i
b
r
a
t
i
o
n
l
i
m
i
t
s
:
-
2
0
%
~
+
2
0
%
Be sure to read CAUTIONS. ( Calibration available after 5 Sec.)
A
U
T
O
E
L
E
X
A
U
T
O
E
L
E
X
A
U
T
O
E
L
E
X
A
U
T
O
E
L
E
X
Page view 0
1 2

Summary of Contents

Page 1 - Cleaning Cautions

Digital Incubator www.R-com.co.kr󰚟PX-20D, PX-20DUSB(Professional)Ver E 3.1New Rcom Pro 20 USER'S MANUALNew Rcom Pro 20 USER'S MANUALSpecies

Page 2 - Turn

- COMPANY - TEL- FAX- E-MAIL: #612 DukAm-Ri, JuChon-Myeon, : GimHae-City, GyeongNam, KOREA: 82-55-337-2560 (Direct to sales team): 82-55-337-2561-3, 2

Comments to this Manuals

No comments